国产精品精品自在线拍,成av人电影在线观看,把女人弄爽特黄a大片3人,久久天天躁夜夜躁狠狠i女人

Fluke 116/323 HVAC Combo Kit - Includes Multimeter and Clamp Meter

  • Fluke 116/323 HVAC Combo Kit - Includes Multimeter and Clamp Meter
  • Fluke 116/323 HVAC Combo Kit - Includes Multimeter and Clamp Meter
  • Fluke 116/323 HVAC Combo Kit - Includes Multimeter and Clamp Meter

主要特性

Fluke 116 Digital Multimeter. Designed by Electricians. Engineered by Fluke.

  • Built-in thermometer for HVAC applications
  • Microamps to test flame sensors
  • Low input impedance: helps prevent false readings due to ghost voltage
  • Large white LED backlight to work in poorly lit areas
  • Resistance, continuity, frequency and capacitance
  • Min/Max/Average with elapsed time to record signal fluctuations
  • Compact ergonomic design for one-handed operation
  • Compatible with optional magnetic hanger (ToolPak?)
  • CAT III 600 V safety rated

Fluke 323 True-rms Clamp Meter. Rugged. Reliable. Precise.

  • 400 A AC current measurement
  • 600 VAC and DC voltage measurement
  • True RMS AC voltage and current for accurate measurements on non-linear signals
  • Resistance measurement up to 40 kΩ with continuity detection
  • Slim, ergonomic design
  • CAT IV 300 V/CAT III 600 V safety rating

產(chǎn)品概述: Fluke 116/323 HVAC Combo Kit - Includes Multimeter and Clamp Meter

Having the right tool for the job is essential. Having all the right tools when you need them is even better. The Fluke 116/323 HVAC Combo Kit gives you the best in a versatile, rugged multimeter and a fast-acting, general purpose clamp meter.

The Fluke 116 comes with the Fluke 80BK-A integrated DMM temperature probe; no need to carry a separate thermometer. The microamp function allows flame sensor measurement down to 0.1 microamps. The AutoV/LoZ function prevents false readings caused by ghost voltage. The Fluke 116 also has a large white LED backlight for work in poorly lit areas. It measures resistance, continuity, frequency, and capacitance and provides Min/Max/Average readings with elapsed time to record signal fluctuations.

Fluke 116 multimeters are independently tested for safe use in CAT III 600 V environments.

True RMS measurements and optimized ergonomics make the Fluke 323 True RMS Clamp Meter the best general purpose clamp meter for commercial and residential electricians. The Fluke 323 model is ideally suited for current measurements up to 400 A in tight cable compartments.

Together, the Fluke 116 HVAC Multimeter and 323 True RMS Clamp Meter give electricians the right tools for the job.

產(chǎn)品規(guī)格: Fluke 116/323 HVAC Combo Kit - Includes Multimeter and Clamp Meter

Fluke 116 HVAC Multimeter with Temperature and Microamps

Specifications
Maximum voltage between any terminal and earth ground600 V
Surge protection6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Display6,000 counts, updates 4 per second
Bar graph33 segments, updates 32 per second
Operating temperature-10°C to +50°C
Storage temperature-40°C to +60°C
Battery type9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery life400 hours typical, without backlight
Accuracy Specifications
DC millivoltsRange/Resolution600.0 mV / 0.1 mV
Accuracy±([% of reading] + [counts]): 0.5% + 2
DC voltsRange/Resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy±([% of reading] + [counts]): 0.5% + 2
Auto voltsRange/Resolution600.0 V / 0.1 V
Accuracy2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivolts1 True RMSRange/Resolution600.0 mV / 0.1 mV
Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMSRange/Resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
ContinuityRange/Resolution600 Ω / 1 Ω
AccuracyBeeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
OhmsRange/Resolution600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
Accuracy0.9% + 1
Range/Resolution40.00 MΩ / 0.01 MΩ
Accuracy1.5% + 2
Diode testRange/Resolution2.000 V / 0.001 V
Accuracy0.9% + 2
CapacitanceRange/Resolution1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
Accuracy1.9% + 2
Range/Resolution> 1000 μF
Accuracy5% + 20%
LoZ capacitanceRange1 nF to 500 μF
Accuracy10% + 2 typical
Temperature2 (Type-K thermocouple)Range/Resolution-40°C to 400°C / 0.1°C
Accuracy1% + 102
Range/Resolution-40°F to 752°F / 0.2°F
Accuracy1% + 182
AC μamps True RMS (45 Hz to 500 Hz)Range/Resolution600.0 μA / 0.1 μA
Accuracy1.0% + 2
DC μampsRange/Resolution600.0 μA / 0.1 μA
Accuracy1.0% + 2
Hz (V or A input)2Range/Resolution99.99 Hz / 0.01 Hz
999.99 Hz / 0.1 Hz
9.999 Hz / 0.001 Hz
50.00 Hz / 0.01 Hz
Accuracy0.1% + 2
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
? Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
? Temperature Range/Resolution: -40°F to 752°F / 0.2°F
Mechanical and General Specifications
Size167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight550 g
Warranty3 years

Fluke 323 True-rms Clamp Meter

Specifications
AC currentRange400.0 A
Accuracy2% ±5 digits
(45 Hz to 65 Hz)
2.5% ±5 digits
(65 Hz to 400 Hz)
AC voltageRange600.0 V
Accuracy1.5% ±5 digits
DC voltageRange600.0 V
Accuracy1.0% ±5 digits
ResistanceRange/Resolution400.0 Ω/ 4000 Ω
Accuracy1.0% ±5 digits
Continuity≤ 70 Ω
AC responseTrue-rms
Data holdYes
SizeH x W x D (mm)207 x 75 x 34
Max wire diameter30 mm (600 MCM)
Weight265 g
Category ratingCAT III 600 V
CAT IV 300 V
WarrantyTwo-year

型號: Fluke 116/323 HVAC Combo Kit - Includes Multimeter and Clamp Meter

Fluke 116/323 Kit
Fluke 116/323 HVAC Combo Kit
Includes Multimeter and Clamp Meter

Includes: Fluke 116 HVAC Multimeter with Temperature and Microamps Fluke 323 True-rms Clamp Mete