New features in recent MET/CAL software versions

New in the latest release MET/CAL (v10.2) improvements:

  • New FSC for Fluke 5322A lets you fully automate calibration of the Electrical Safety Calibrator
  • New FSC for Fluke 8558A to automate the 8.5-digit Multimeter calibration
  • New FSC for Fluke 4180 and Fluke 4181 for automated calibration of IR thermometers
  • Enhanced results saving and improved error logging for failures
  • Easy collection of log files with a single click to provide to technical support for assistance without needing to comb through multiple separate files
  • Upgraded Procedure Editor for better usability and more choices for procedure writers
  • Upgraded instrument configuration screen for better usability, a more modern user interface and better control when moving and resizing windows
  • More meaningful and useful error messages

MET/TEAM (v3.0) improvements:

  • Significant speed improvements
  • Increased flexibility in Manual Templates
  • Improved Data Check editor makes it easier to set up customized data checks and access more of MET/TEAM with them
  • MET/TEAM API to interface with other applications, making it easier and safer to transfer data between applications
  • Dynamic calculation of manual template limits; when you change a set point tolerances are calculated automatically, providing better flexibility

What are you missing? Having the latest version of MET/CAL software gives you access to many new features and functions. Here are just a few examples of the additional capabilities added with each new update.

New features in recent MET/CAL software versions

Features9.09.19.210.0/10.110.2
New Runtime user interface
??????
User-group-based security
??????
Test results data export
??????
Windows 10 compatibility
??????
Settings stored directly in database
??????
One workstation supporting multiple configurations
??????
Automatic migration of legacy formatted procedures (PROC.DIR) to projects and PXEs
??????
New procedure directory scheme for improved security and version control
??????
Language support for MET/CAL - German, Russian, French, Spanish, Portuguese, Chinese, Italian, and Japanese
??????
Global Unique Identifiers allowing access to SQL server replication
??????
FSC Support for the Rohde & Schwarz NRPT sensor series for the Fluke Calibration 96270A
??????
Enhanced results save process to MET/TEAM with improved logging
??????
Support for?MET/CONNECT?as an alternative backend to MET/TEAM
??????
FSC Support for the Fluke 5790B and Fluke 8588A
??????
Additional logging and data saving improvements with both MET/TEAM and MET/CONNECT
??????
FSC Support for the Fluke 5322A, Fluke 8558A, Fluke 4180, and Fluke 4181
??????
Modernized Instrument Configuration Dialogs
??????