COMPASS for molbox PC Based Software Demo (.exe)
COMPASS for molbox PC Based Software Upgrade (.exe)
TITLE | VER | USE WITH |
COMPASS? for molbox? | 4.06 2010.10.28 |
TITLE | VER | USE WITH |
COMPASS? for molbox? | 4.06 2010.10.28 | molbox1, molbox1+, molbox RFM |
Description |
This download file provides 100 hours of fully functioning use of COMPASS for molbox. Licensed users can download this file to upgrade from a previous version of COMPASS for molbox. ? |
Summary |
COMPASS for molbox is a complete flow calibration software package for users of Fluke Calibration molbloc/molbox mass flow calibration systems. Using COMPASS for molbox, you can create any number of calibration test scenarios; define characteristics of various devices under test (DUT); run tests; analyze test data and generate reports without ever leaving the program or you can export test data for analysis using other applications.
COMPASS for molbox is an application to automate flow calibration using molbox as the reference. It provides the missing link needed to get from automated hardware components to a fully automated flow calibration system... and without consuming your internal engineering resources or facing the uncertainty usually associated with getting automated systems on-line. |
Instructions: |
Demo Download and execute the self extracting executable file. The file activates the COMPASS for molbox installation program. Follow the instructions to install the demo.
This demo expires after 100 hours of full use of COMPASS.
Upgrade Download and install the upgrade into the same directory as your existing licensed version to automatically upgrade COMPASS. If you wish to install to a different directory or computer, you must first install the older version, then the upgrade, or copy the "COMPASS. lis" file from the installation directory of the licensed version to the installation directory of upgrade. |
Updates Include: |
Rev 4.06 (2010.10.28) CHG (CMB-731) Changed the program splash screen to include FLUKE-Calibration. FIX (CMB-730) Resolved a problem that could generate an invalid setup error when running a test on a voltage/current DUT. FIX (CMB-720) DUT temperature may display a value that is off by a conversion factor between temperatures (e.g. C -> F). FIX (CMB-2) Corrected a problem that can generate "The molboc has not changed. Continue anyway?" when switching blocs in the middle of a test. FIX (CMB-1) Version 4.05 was incorrectly displayed as 4.5 in the About dialog.
Rev 4.05 (2009.12.15) ADD: Support molbox1+ v6.00 and named calibration molblocs. FIX: “Object variable or with block variable not set…”, error 91, occurs when running a test without a molbox. FIX: Unexpected message box displays when the "ESC" is pressed during hardware setup. FIX: When running a "Run molbox" test, the DUT temperature unit is not updated on DUT screen. FIX: File Upgrade Wizard menu enabled while running a test. FIX: MFC-CB Reference does not apply K factor to Flow value.
Rev 4.04a (2008.10.14) FIX: Copy COMPASS Configuration feature did not work properly. FIX: Compass tries to create a file in \Program Files\Compass for Molbox, which yields an error on Vista with User Account Control turned on.
Rev 4.04 (2008.10.14) ADD: The ability to verify and change the molbox serial number during initialization if desired. ADD: Default file locations and installation modified to be compliant with Windows Vista. CHG: Updated help file. CHG: Remove "What's this" help to be compliant with Windows Vista. FIX: Demo COMPASS for molbox software does not work on computers with Regional Settings other than "English (United States)." FIX: When installed on a PC that already has COMPASS for Pressure, COMPASS for molbox looks for PROGAS.MDB in the C4P directory. FIX: NI DeviceNet address was not saved properly. FIX: [Setup][Hardware][Flow], and then "new" icon yields "Type Mismatch" error.
Rev 4.03b (2007.02.01) ADD: Both molbloc SN's display on the report when A+B mode is used. CHNG: Running a test with BPR Auto active in molbloc A+B mode generates a specific error message identifying BPR Auto mode as an A+B an invalid combination. FIX: DUT records upgraded from versions prior to 4.02 are no longer lost. FIX: The output of a DMM preceeded by "+" is now handled properly. FIX: Actual flow units for the molbloc flow use the DUT's pressure and temperature for the flowing conditions. FIX: A DUT that uses an actual flow unit and a proportional density correction caused a faulty reference flow in DUT's conditions value. FIX: COMPASS does not properly report (on screen or in data file) when user selects A+B mode during test.
Rev 4.03a FIX: Changing the DUT range now correctly updates the
|